Home › Help & Advice › Hot Water › No Hot Water
Hot Water

No Hot Water? Causes and How To Fix It

Reviewed by our Gas Safe registered engineers  ·  Last updated 21 July 2026

No hot water from the taps has a handful of usual causes — a stuck diverter valve, a thermostat or timer setting, low pressure, or (on stored systems) the immersion. Here’s how to work through them safely.

Gas Safe 918817 North London specialists Upfront pricing

No Hot Water — Troubleshooting Guide
Gas Safe Registered 918817
160 Google Reviews
North London specialists
24/7 emergency cover

Quick answer: If you have heating but no hot water, the diverter valve is the usual culprit. No hot water at all can be low pressure, a thermostat or timer setting, or — on stored-cylinder systems — the immersion or programmer. Check pressure and the timer first; a stuck diverter needs an engineer.

Common Causes

Why there’s no hot water

These are the usual causes, roughly in order. The colour on the left shows whether it’s a safe homeowner check or a job for an engineer.

What you seeLikely causeWhat to do
Heating works, no hot waterDiverter valve stuckNeeds an engineer to free or replace it
No hot water at allLow pressure or lockoutCheck the gauge; repressurise to ~1.3 bar
Hot water only lukewarmDiverter partly stuck or scaleBook an engineer to check the diverter
No hot water, stored cylinderImmersion or timer faultCheck the timer and thermostat; test the immersion
Hot then quickly goes coldFlow rate or diverter faultAn engineer can diagnose it
No hot water in cold weatherFrozen condensate lockoutThaw the external pipe, then reset
Safe Checks

What you can safely check

Safe to check

  • The pressure gauge reads ~1.3 bar (top up if low)
  • The hot-water timer/programmer is set to come on
  • The cylinder thermostat (if you have one) is set to about 60°C
  • In winter, the external condensate pipe hasn’t frozen

Book an engineer if…

  • You have heating but no hot water (classic diverter fault)
  • Water is only ever lukewarm however long you run it
  • You can smell gas — leave and call 0800 111 999
Engineer Insight

What we usually find

On combi boilers, ‘heating fine but no hot water’ is nearly always the diverter valve — it sticks on the heating position and won’t switch to hot water. It’s a common, fixable part. On stored-cylinder systems it’s more often the immersion, the cylinder thermostat, or the programmer. We confirm which before quoting.

Costs

What repairs typically cost

Diagnostic visitFault-find & upfront quote£80–£120
Diverter valve replacementParts & labour£150–£320
Immersion or cylinder statParts & labour£120–£260

Typical North London guide prices — you’ll always get an upfront quote before any work starts.

FAQs

No hot water — your questions answered

On a combi boiler this is almost always the diverter valve — it’s stuck in the heating position and won’t divert to hot water. It’s a common, fixable part an engineer can replace.

Yes. If pressure drops too low the boiler locks out and won’t heat water or radiators. Top up to about 1.3 bar with the filling loop and see if it restarts.

Check the programmer is set to heat water and the cylinder thermostat is at about 60°C. If the boiler is fine, test the immersion heater as a backup. If unsure, we can diagnose it.

Usually a partly-stuck diverter or scale in the heat exchanger. Both reduce how hot the water gets. An engineer can free the diverter or descale the exchanger.

A diagnostic visit is typically £80–£120 in North London. A diverter valve replacement runs about £150–£320. You’ll always get an upfront quote first.

No hot water? We’ll get it back.

Book a Gas Safe engineer to check the diverter, immersion or pressure, or call and tell us what’s working and what isn’t — we’ll give you an honest steer first.

Gas Safe Registered 918817  |  North London specialists  |  Upfront pricing

Related Koncore servicesNo hot water from the taps? Our Gas Safe engineers can help — book a boiler repair in North London. Contact our team or see the areas we cover.